- Operating range: from 1 to 470 m3/h with head up to 63 metres.
- Maximum operating pressure: 16 bar – 1600 kPa (for DN 200 max 10 bar).
- Installation: normally in the horizontal position.
- Liquid temperature range: from -10 °C to +140 °C.
Showing 25–32 of 352 results
-
DAB Centrifugal Pump KDN
Description : Standardised centrifugal single-stage pumps, designed for a wide range of applications, such as: Water supply. Hot water circulation for the heating system. Circulation of cold water for air conditioning and refrigeration systems. Transfer of liquids in agricultural, horticultural, and industrial environments. Installation of pumping assemblies. They can be coupled, using an elastic joint (standard or spacer), to a 2-pole or 4-pole electric motor, and installed on a formed metal sheet base in accordance with UNI EN 23661.- Operating range: flow up to 470 m3/h, head up to 143 metres.
- Maximum operating pressure: 16 bar – 1600 kPa (for DN 200 max 10 bar).
- Installation: normally in the horizontal position.
- Pumped liquid temperature range: from -10°C to +140°C.
-
DAB Centrifugal Pump KI
Description : Single-impeller stainless steel end suction centrifugal pump, suitable for thermal waters, industrial washing, civil and industrial pressure boosting (cold, hot, refrigerated liquid).- Operating range: flow rate up to 11 m3/h, with head up to 40 meters
- Maximum operating pressure: 8 bar
- Liquid temperature range: from -10°C to +90°C
- Installation: horizontal or vertical position, provided that the motor is always above the pump
-
DAB Centrifugal Pump K TWIN IMPELLER
Description : Twin-impeller centrifugal pump designed for the realisation of pressurization units in water systems and filling of pressure vessels. Suitable for sprinkler systems and other general water supply uses.- Operating range: from 1,2 to 30 m3/h with head up to 97 metres.
- Maximum operating pressure: K 35/40, K 35/100, K 40/100 :6 bar (600 kPa). K 45/50, K 55/50 :8 bar (800 kPa). K 55/100, K 66/100 :10 bar (1000 kPa). K 90/100, K 70/300, K 80/300, K 70/400, K 80/400 :12 bar (1200 kPa).
- Installation: fixed, horizontal or vertical position, provided that the motor is always above the pump.
- Liquid temperature range: K 35/40, K 45/50, K 35/100, K 40/100, K 55/100: from -10 °C to +50 °C. K 55/50, K 66/100, K 90/100, K 70/300, K 80/300, K 70/400, K 80/400: from -15 °C to +110 °C.
-
DAB Centrifugal Pump K SINGLE IMPELLER
Description : Single-impeller centrifugal pump suitable for domestic, civil, industrial and agricultural systems, and for decanting, mixing and irrigation uses. Operating range: from 1,8 to 96 m3/h, with head up to 62 metres. Maximum operating pressure: K 20/41, K 30/70, K 30/100, K 36/100, K 12/200, K 14/400 : 6 bar (600 kPa), K 36/200, K 40/200, K 55/200, K 11/500, K 18/500, K 28/500 : 8 bar (800 kPa), K 40/400, K 50/400, K 30/800, K 40/800, K 50/800, K 20/1200, K 25/1200, K 35/1200 : 10 bar (1000 kPa) Installation: horizontal or vertical position, provided that the motor is always above the pump. Liquid temperature range: K 20/41, K 30/70, K 30/100, K 36/100, K 12/200, K 36/200, K 40/200 : from -10 °C to +50 °C. Remainder of the range: from -15 °C to +110 °C. Download : -
DAB Centrifugal Pump NKM-G, NKP-G
Description : Standardised centrifugal monobloc electric pumps with coupling, designed for a wide range of applications, such as: water supply, hot water circulation for the heating system, circulation of cold water for air conditioning and refrigeration systems, transfer of liquids in agricultural, horticultural, and industrial environments, installation of pumping assemblies.- Operating range: from 1 to 460 m3/h with head of up to 96 metres.
- Maximum operating pressure: 16 bar – 1600 kPa (for DN 200 max 10 bar).
- Installation: normally in horizontal or vertical position, provided that the motor is always above the pump.
- Liquid temperature range: from -10°C to +140°C.
-
DAB Electronic Centrifugal Pump KDNE MCE-P
Description : Standardised centrifugal electronic pumps on base with elastic coupling, designed for: circulation of the hot water of the heating system, of the cold water of the air conditioning and refrigeration systems.- Operating range: from 1 to 470 m3/h with head up to 63 metres.
- Maximum operating pressure: 16 bar – 1600 kPa (for DN 200 max 10 bar).
- Installation: normally in the horizontal position.
- Liquid temperature range: from -10 °C to +80 °C.
-
DAB Electronic Centrifugal Pump KDNE MCE-C
Description : Standardised centrifugal electronic pumps on base with elastic coupling, designed for: circulation of the hot water of the heating system, of the cold water of the air conditioning and refrigeration systems.Related Products
-
DAB Fire Fighting Systems Pump 1 KDN COMPACT
Fire-fighting booster sets with electric and diesel pumps, designed to meet the needs of automatic fixed sprinkler or hydrant fire-fighting systems of commercial buildings, in compliance with standard EN12845.- Operating range: from 10 to 650 m2/h – Max head: 12 bar (120 m).
- Power range for electric and diesel pumps: up to 110 kW.
- Max pressure: 16 bar – PN16.
- Liquid temperature range: from 0°C to +70°C.