ELECTRONIC IN-LINE PUMPS

Hot or cold water circulation pump with in-line ports, suitable for installation directly on the pipework of civil and industrial heating, air conditioning, refrigeration etc.

2.1

CPE-CP-GE-DCPE-DCP-GE

Electronic In-Line Pumps

In-line port circulation pumps, suitable for heating, air conditioning, refrigeration and sanitary water systems. Particularly versatile thanks to the use of the MCE/C inverter, offering performance features capable of automatically adapting to the different needs of the system, keeping a consistent differential pressure. Available in the single and twin versions.

Operating range from 1,2 to 230 m3/h with head up to 56 metres.
Working pressure 16 bar (1600 kPa).
Liquid temperature range -10 °C to +130 °C for DN 40 – 50. -10 °C to +140 °C for the remainder of the range.
Flanging PN 16.
2.2

CME-CM-GE-DCME-DCM-GE

Electronic In-Line Pumps

In-line port circulation pumps, suitable for heating, air conditioning, refrigeration and sanitary water systems. Particularly versatile thanks to the use of the MCE/C inverter, offering performance features capable of automatically adapting to the different needs of the system, keeping a consistent differential pressure. Available in the single and twin versions.

Operating range from 1,2 to 360 m3/h with head up to 34 metres
Working pressure 16 bar (1600 kPa).
Liquid temperature range -10 °C to +130 °C for DN 40 – 50. -10 °C to +140 °C
for the remainder of the range.
Flanging PN 16.
2.4

KLME-KLPE-DKLME-DKLPE

Electronic In-Line Pumps

Hot or cold water circulation pump with in-line ports, suitable for installation directly on the pipework of on civil and industrial heating, air conditioning, refrigeration, and sanitary water plants. Particularly versatile thanks to the use of the MCE/C inverter, offering performance features capable of automatically adapting to the different needs of the system, keeping a consistent differential pressure.

E.SYBOX is DAB’s new integrated system for pressurization in domestic and residential areas.
E.SYBOX does not require any additional components for installation. It consists of a self-priming multistage pump, electronic inverter management, flow and pressure sensors, high-resolution swivel LCD display and an integrated 2 liter expansion tank. It can be installed both vertically and horizontally and even in tight spaces without a high air exchange. The water-cooled engine, the hull protection in ABS with sound-absorbing function, the vibration damping feet and electronics make it an absolutely quiet (45 dB) and compact. The wireless device facilitates the creation of pressurization units and connectivity with other DAB devices.
Operating range from 2 to 67 m3/h with head up to 13,7 metres.
Working pressure 10 bar (1000 kPa).
Liquid temperature range from -15 °C to +120°C
Standard flanges DN 40, DN 50, DN 65, DN 80 – PN 6/PN 10 (4 holes).
2.3

ALME – ALPE

Electronic In-Line Pumps

Hot or cold water circulation pump with in-line ports, suitable for installation directly on the pipework of on civil and industrial heating, air conditioning, refrigeration, and sanitary water plants. Particularly versatile thanks to the use of the MCE/C inverter, offering performance features capable of automatically adapting to the different needs of the system, keeping a consistent differential pressure.

E.SYBOX is DAB’s new integrated system for pressurization in domestic and residential areas.
E.SYBOX does not require any additional components for installation. It consists of a self-priming multistage pump, electronic inverter management, flow and pressure sensors, high-resolution swivel LCD display and an integrated 2 liter expansion tank. It can be installed both vertically and horizontally and even in tight spaces without a high air exchange. The water-cooled engine, the hull protection in ABS with sound-absorbing function, the vibration damping feet and electronics make it an absolutely quiet (45 dB) and compact. The wireless device facilitates the creation of pressurization units and connectivity with other DAB devices.
Operating range from 1 to 8,4 m³/h with head up to 21 metres.
Working pressure 10 bar (1000 kPa).
Standard voltage single-phase 220-240 V, 50/60 Hz
Liquid temperature range from -15 °C to +120 °C.

IN-LINE PUMPS

Hot or cold water circulation pump with in-line ports, suitable for installation directly on the pipework of civil and industrial heating, air conditioning, refrigeration etc.

inline1.1

CM, CM-G / DCM, DCM-G

In-Line Pumps

In-line port circulation pumps, suitable for heating, air conditioning, refrigeration and sanitary water systems.
Available in the single and twin versions.

Operating range from 1,2 to 420 m3/h with head of up to 41 metres.
Maximum operating pressure PN10: for DN 40 – DN 50. PN16: Remainder of the range.
Liquid temperature range from -10 °C to +130 °C for DN 40 – DN 50. from -10 °C to +140 °C for the remainder of the range.
Flanging PN 16.
inline1.2

K-HA

In-Line Pumps

The K-HA single impeller centrifugal pump is designed for boosting water pressures in houses and apartments (domestic properties), in order to provide additional pressure to hot and cold water taps and similar outlet points. The K-HA centrifugal pump is mainly intended for use in open vented systems(tanks), but may also be installed directly on the incoming water mains supply feeding a boiler, subject to the approval of the local Water Authority. The pump incorporates a flow switch that starts and stops the pump in line with the flow, when a tap is opened or closed. The pump is supplied with a 0,3 meter power cable.

Operating range up to 4,2 m3/h with head up to 22 m.
Maximum Operating Pressure 4 bar (liquid temperature 35° C), 2 bar (liquid temperature 65° C).
Liquid temperature range from 0 °C to +100 °C.
Humidity ≤ 95%.
inline1.3

KC, KCV

In-Line Pumps

Pumping of water or other non-aggressive, non-explosive liquids, free from solid particles or fibres.
Particularly suited for pumping water containing glycol for air conditioning systems.

Operating Range from 3 to 45 m3/h with head of up to 24 metres.
Maximum operating pressure 6.5 bar
Liquid temperature range from -10 to +55 °C
Maximum glycol percentage up to 40 %.